Sanitary Diaphragm Valves for High-Purity Process Piping Applications
- 3A Manual Diaphragm Valves
- 316L Stainless Steel for Fluid Contact
- Working Pressure 10 Bar
- EPDM Sealing: -20℃ ~ 135℃ (150℃ Max 20min)
- VMQ Sealing Optional
This 3/4" sanitary hand-actuated diaphragm valve utilizes 316L stainless steel surfaces for excellent corrosion resistance and sanitation properties that are perfect for aseptic applications. It is designed to have a smooth, dead-space-free interior that protects against contamination, complying with rigorous sanitary regulations, including 3A. Furthermore, it can be operated manually for accurate fluid management. It can be used in the pharmaceutical industry as well as in the food and beverage industries where sanitary fluid handling is crucial in narrow pipe systems.
Product Overview
The Eagle 3A Manual Diaphragm Valve in the 3/4 in. size performs the same absolute process isolation as other bigger valves but in a compact design intended for smaller hygienic piping. All areas in contact with fluids are made of 316L stainless steel providing a good resistance to cleaning agents and process fluids. The handwheel-activated compressor compresses a flexible diaphragm to the precision weir forming a tight barrier isolating the process fluid from the outer environment. The valve is particularly designed for sterile sampling lines, small transfer batches, and utilities’ connections when larger valves become oversized and do not bring any benefit.
Technical Specifications
- Size: 3/4" (Other sizes available: 1/2" to 2")
- Body Material (Fluid Contact): 316L Stainless Steel
- Working Pressure: 10 Bar (145 PSI)
- EPDM Sealing Temperature: -20℃ to 135℃ (150℃ Max for 20 minutes)
- Optional Sealing: VMQ (Silicone)
- Certification: 3A Sanitary Standard, ASME BPE Compliant
- Connection Type: Tri-Clamp (Bevel Seat)
- Operation: Manual Handwheel
Key Advantages of Our Sanitary Diaphragm Valve
Dimensions

| Size | L (mm) | L1 (mm) | K (mm) | D (Tube OD, mm) | C (Ferrule OD, mm) | H (Overall Height, mm) |
|---|---|---|---|---|---|---|
| 0.5" | 108 | 102 | 65 | 12.7 | 50.5 | 103 |
| 0.75" | 126 | 120 | 87 | 19.05 | 50.5 | 103 |
| 1" | 126 | 120 | 87 | 25.4 | 50.5 | 122 |
| 1.5" | 160 | 140 | 104 | 38.1 | 50.5 | 160 |
| 2" | 193 | 150 | 114 | 50.8 | 64 | 190 |
Component Breakdown

| No. | Description |
|---|---|
| 1 | Cap |
| 2 | Handwheel |
| 3 | Screw |
| 4 | Valve Rod |
| 5 | Valve Cap |
| 6 | Valve Core |
| 7 | Diaphragm |
| 8 | Valve Body |
| 9 | Nut |
Installation

For optimal drainage and effective self-drainment properties of the weir devices, it is essential to install the valve with a minimum tilt as illustrated. This guarantees complete drainage during cleaning operations and guarantees that there is no residual liquid left on the sealing surfaces.
Applications & Industries
Frequently Asked Questions
What pipe sizes is a 3/4" diaphragm valve typically used with?
Designed specifically for usage with 3/4-inch OD stainless steel tubing having a real outside diameter of 19.05 mm, the 3/4-inch sanitary diaphragm valve is a widely used valve in pharmaceutical sampling lines, clean utility drops, and small scale processing connections. A full 1-inch valve would be too big for this size. It utilizes standard 3/4-inch Tri Clamp ferrules and uses the same clamp and gasket components as those used in the other sizes.
How do I know when to replace the diaphragm?
It is necessary to change the diaphragm when it starts showing signs of damage including cracking, swelling, permanent deformation, or rough surface which may harbor bacteria. Under conditions of normal CIP, the diaphragm changes will be needed in about 12–24 months of regular operation of the valve with EPDM diaphragm. Whenever the valve is being subjected to aggressive chemicals or frequently undergoes heat treatment (above 135 °C), the replacement time will become shorter. It takes none to inform the technician whenever the diaphragm fails to perform correctly such as leaking or failing to seal properly. Eagle is able to provide the customer with diaphragms that have 40% more durability than the industry standards. In addition, the customer is recommended to keep a spare diaphragm so that it will be possible to repair the valve during maintenance instead of at the time of emergency shutdown.
Can this valve be automated later if manual operation is no longer sufficient?
Absolutely. The Eagle 3A diaphragm valve body has both manual handwheels and pneumatic actuators. If a process that was constructed with manual valves is upgraded to automatic control, then the manual actuator can be replaced by the pneumatic actuator without having to remove the valve body from the pipeline. The modular design helps to protect the initial investment and gives an easy way to upgrade as production increases and needs for automation arise. You can contact Eagle engineering department for actuator sizing and compatibility confirmation for your specific valve size.
What is the correct installation orientation for a weir-type diaphragm valve?
When installing a weir-type diaphragm valve, it is imperative to ensure that the valve body is positioned such that it will be able to drain when the system is emptied. Ideally, the angle of installation should be such that the valve body has a slight incline from horizontal, as indicated in the installation illustration. This position ensures that there will be no liquid left behind on the upstream side of the weir once the line has been drained; this is critical for ensuring the effectiveness of the CIP process and the prevention of microbial growth in the pool of water. The valve can be installed in both horizontal and vertical runs of pipe, provided that the requirement for draining the system is met. Do not have the handwheel of the valve face down, as this may result in accumulation of debris in the area of the stem, making maintenance work difficult.
Why Choose Eagle Valves
Request Custom Quote
Contact our engineers for sizing assistance, diaphragm material selection, or elastomer compatibility guidance
GET PERSONALIZED QUOTATIONResponse within 4 hours | Application analysis | Competitive pricing with full documentation