A sanitary pressure relief valve acts as the last barrier in a sanitary process tank. This is the most commonly specified component by size or price, rather than by the function of the valve itself. The sanitary pressure relief valve protects tanks, lines and pump casings from excess pressure; in addition the vacuum version protects the vessel from collapsing when the vessel is emptied or cleaned.
Quick answer: a sanitary relief valve is typically a spring-loaded device with a clamp connection, constructed with a 316 L body and a food grade seat. They are set to open at predetermined pressure ranges between 0.2 bar — 6 bar. For the majority of installations, there are three configurations: pressure only, vacuum only, and pressure vacuum valve. The sanitary pressure relief valve must be mounted vertically at the highest point on the vessel with no isolation valves in between the vessel and the relief valve; the discharge of the valve must be directed to a safe area. The sizes of sanitary pressure relief valves range from 1 inch to 4 inch tri-clamps, and the price of sanitary pressure relief valves ranges from approximately $120 for a 1 inch pressure relief valve, to $800 for a 3 inch pressure vacuum valve. The installation of sanitary relief valves should verify set pressure at the time of commissioning and at least once each year thereafter.

What It Is Protecting, and From What
The difference that should be noted is between a pressure relief valve and a pressure reducing valve. Pressure relief valves open to prevent equipment from being over-pressurized and then will close once the equipment has relieved itself of that excess pressure. Pressure reducing valves are designed to maintain a lower downstream pressure at the time of normal operation. The distributors may sell the two products, but they are not identical. When comparing the two, it's important to understand that although the two types of products may be manufactured by a single distributor, they cannot be interchanged.
Types: Spring-Loaded, Pressure-Vacuum, Rupture Disc and Pilot-Operated
A rupture disc is not a substitute for a discharge valve in a sanitary application. Rather, the rupture disc provides an additional layer of protection in cases where the rate of increase in pressure is too fast for the spring valve to react, or where fouling of the spring valve's seat by the process fluid might occur. The rupture disc is a disposable item, and replacement costs will depend on how many times it fails.
How It Works: Set Pressure, Spring and Seat
The set pressure is defined as the point at which the disc begins to lift from the seat. The set point is set via the use of a screw thread to compress the spring. In a hygienic application, it is common for the screw adjustment to be locked and the setting marked on the valve body.
The reseating pressure is defined as the point at which the disc returns to the seat, and this pressure will always be lower than the set point. For small sanitary valves, reseating pressure will typically be in the 10% to 20% range of set pressure. If a valve has insufficient reseat pressure or "blowdown" to enable a good seal, it will chatter as it operates, opening and closing rapidly, eventually damaging the valve seat within hours of use.
The seat is what makes the valve sanitary. The use of an elastomeric material like EPDM or silicone as a soft seat will provide a good seal under low pressure, while the use of metal-to-metal seating is not practical in the case of a small sanitary valve. The trade-off is one between the temperature and chemical compatibility and the fact that the seat wears out, which is why the seat is a replaceable component of the valve rather than a permanent component.
The lift for sanitary relief valves is small. The sanitary relief valve opens only a fraction of a millimetre to allow product flow (which is the rated flow) to pass through that small area; therefore, the flow capacity of the sanitary relief valve is determined by the seat diameter, not by how far the disc lifts off the seat. This is also why a partially obstructed inlet or foreign material (product debris) on the seat affects the sanitary relief valve's flow capability.

What Makes It Sanitary Rather Than Industrial
Three specific characteristics are used to distinguish sanitary valves from industrial valves. The first characteristic is "cleanability." That is, sanitary valves do not have dead pockets, threaded fittings or internal areas that will retain product and can be hard to clean. The sanitary valve body is machined so that the fluid pathway is smooth and can be visually examined, and fits are always clamp-type instead of threaded to eliminate the possibility of contamination during assembly.
The second characteristic is surface finish. Sanitary valves have product contact surfaces with a completed surface finish of Ra 0.8 micrometres or better, and this finish must be documented (not just assumed). Residue is what causes cleaning validation failure, and rougher surfaces tend to trap residue.
The third characteristic is material and elastomer documentation. A sanitary valve should be made of 316L body material and use FDA-compliant elastomers and, if necessary, meet USP Class VI requirements. Certificates must be provided for all material specifications and elastomers. A valve may be rated for pressure and not be classified as a sanitary valve for a pharmaceutical application, irrespective of what is stated in the catalog.
The definition of a sanitary pressure-relief valve lists three specific features (cleanability, surface finish and documentation) that define the specification for a sanitary pressure-relief valve and how they differ from the definition of a valve that appears shiny and polished but does not comply with 3A standards.
Set Pressure Ranges and How to Specify One
Sanitary pressure relief valves are manufactured with a small range of set pressures, because sanitary vessels do not operate as industrial pressure vessels. The nominal operating pressure of sanitary pressure relief valves ranges from 0.2 to 6 bar; most dairy and beverage processing facilities use sanitary pressure relief valves with nominal operating pressures of 0.5 to 3 bar.
When the nominal operating pressure drops below 0.2 bar, the sanitary pressure relief valve becomes a vent; when the nominal operating pressure exceeds 6 bar, the corresponding application is typically associated with ASME stamped pressure-vessel devices, rather than clamp-style sanitary valves.
There are two factors associated with the set point for sanitary pressure relief valves: (1) The set point cannot exceed the design pressure of the sanitary vessel; and (2) The set point must be above the normal operating pressure of the sanitary vessel so that the sanitary pressure relief valve does not open due to the normal operating pressure and surge produced by the sanitary vessel and/or sanitary process.
In practice, the set point for sanitary pressure relief valves will be a minimum of 10 to 25 percent higher than the maximum operating pressure, allowing for the pressure surge and providing an adequate margin for the protection of the sanitary vessel. There is also a third factor related to the sanitary pressure relief valve — flow capacity. The purpose of a valve is to open at the proper pressure, yet if it cannot allow fluids at greater than the pump's capacity to flow through it, the vessel will remain under pressure above the set point, as the pressure will keep increasing until there is equal flow through the valve and into the vessel. Many people design their valves solely on the basis of the pre-determined set-point for pressure, but this is a very common mistake and should be avoided.
Materials and Elastomer Choice
| Component | Standard | Alternative | Chosen when |
|---|---|---|---|
| Body | 316L stainless | 304 for non-corrosive duty | Always 316L on product contact |
| Spring | 316 stainless | Alloy for chloride duty | Coastal or brine applications |
| Seat and seal | EPDM | Silicone, FKM, PTFE | Temperature and chemical compatibility |
| Surface finish | Ra 0.8 micrometres | Ra 0.4 for pharmaceutical | Cleaning validation requirement |
| Connection | Tri-clamp | Threaded or weld end | Clamp for cleaning, weld for permanent |
In general, the body of the valve will normally be 316L stainless steel to provide a clean surface for product contact, and if the application is non-corrosive, then 304 stainless steel is an acceptable alternative. The spring will be 316 stainless or a spring alloy suitable for chloride applications. An application using coastal or brine cleaning processes may benefit from using a non-corroding alloy for its internal workings. It is a common misconception that there is only one choice of seat and seal for use in the way of cleaning. A cleaning validation must be performed on both the valve body and seat and the cleaning fluids must be sufficiently compatible with the elastomer used in the seat and seal. The most common elastomer used for seat and seal applications is EPDM (ethylene propylene diene terpolymer rubber), as EPDM is suitable for use in the cleaning of all CIP (clean in place) cleaning processes as well as for moderate to high-temperature applications. For products that are fatty in nature or require high temperatures, silicone will be used as the elastomer of choice. For applications using oils or solvents, FKM (fluorocarbon) is often selected. Where maximum chemical resistance is necessary, PTFE (polytetrafluoroethylene) is often specified, as there is no need for it to be flexible or elastic. The material used for the selection of elastomers in most cases will be determined by the cleaning class rather than by the product that is being cleaned because the valve spends significantly more time in contact with the cleaning solution than with the product in a properly operated facility. A caustic leak from a seat means that the seat has already failed within a week of the first Clean in Place (CIP) cycle.
Where It Is Installed, and the Rules of Location
The valve must be mounted vertically at the highest point of the vessel (i.e., above the fluid level) on a large, short nozzle either by mounting the valve to the top of the vessel or mounting the valve to a separate connection point within the vessel.
The orientation is not a matter of preference, because a spring-operated pressure relief valve relies on the gravitational pull of the weight of the Valve's Seat and also a balanced load, if the valve is mounted either at an angle or upside down the pressure relief valve will not reseat properly.
However, the short length of the nozzle is also considered important because the amount of back pressure (i.e., Pressure Drop) within the Inlet will lower the amount of Pressure seen by the Valve, and therefore a long length of Inlet and/or an undersized Inlet means that the fluid within the vessel would have to have an established pressure above that established before the Pressure Relief Valve opens.
There must be no means to isolate the Vessel or Relief Valve unless by using a Locking/Interlocking System. If the valve is isolated during maintenance, the isolation must be locked open again when the maintenance is complete.
The Point of Discharge for any Relief Valves must be in a Safe Area, otherwise discharging onto an area such as a concrete floor would be considered a slip hazard and would also create a contamination event and the Discharge into a Closed Piped System with Restrictions will not provide the Rated Flow Capacity of that Relief Valve. The pipe is connected directly to a waste, a holding tank, or outside. There is no valve between pipe and valve; the pipe size should match the valve outlet.
At the time of installation, it is essential to understand the ways that a relief valve can fail during its useful life. When a valve constantly leaks, this indicates an issue with the seat, whereas an incorrect set pressure has different solutions than an incorrectly adjusted pressure setting.

Installation Mistakes That Defeat the Valve
While a relief valve will be installed to protect a pressure vessel, there are five significant reasons why the installation of the relief valve does not provide the necessary protection.
- The inlet nozzle is too small and results in a drop in pressure that increases the setpoint at which the vessel operates.
- A discharge pipe with an obstructing valve or pipe.
- When the valve is installed on a common manifold with another device, it will read the pressure on the other device instead of the pressure in the vessel.
- The pressure set above the normal pumping discharge point will lift the valve on each startup and will eventually damage the valve seat.
- The valve is installed based on the connection size instead of the flow capacity.
The last one is the most costly mistake because it appears to be done correctly. If the 2-inch valve has only a 1-inch opening in its seat, it will be able to allow flow equal to that of a 1-inch valve, and therefore a customer who ordered a "2-inch" valve will receive a valve with 2-inch connections, but not 2-inch capability.
Cleaning, CIP and Verification
In a sanitary processing facility, the relief valve is part of the cleaning system, but it is one of the cleaning system components that are most frequently neglected during cleaning activities.
The valve experiences the effects of cleaning solutions at the time of the cleaning, and the seat will move slightly (either upward or down, or leaks), which are the very conditions that will clean the seats. If a relief valve has either been isolated during the cleaning process, or has been set for a pressure that prevents it from lifting, the valve will not be served by a cleaning and will provide an opportunity for contamination.
Most quality assurance programs perform annual verifications on relief valves through the use of bench testing, instead of simply relying on the markings placed on the valve. A spring will lose its tension, and the valve seat will change shape, which means that a relief valve that was initially set for a pressure of two bar (this was three years ago) could now open at 1.6 bar and cause minimal risk, or at 2.4 bar and present a serious risk, if the vessel can safely operate at 2.5 bar.
Between verification events, customers are advised to conduct visual inspections of relief valves: seat weeping, product residue in the outlet of the relief valve, a damaged relief valve cap, and a loose relief valve lock nut. Replace parts during service. The seat and seal are included as replacements, while the spring may be replaced if the set pressure cannot be returned to within the specified tolerances.
Price Bands and What Moves Them
| Configuration | Size | Indicative price | What moves it |
|---|---|---|---|
| Pressure only, EPDM seat | 1 inch | $120 to $220 | Set range, finish, certificate pack |
| Pressure only, EPDM seat | 1.5 inch | $180 to $320 | Flow capacity, body machining |
| Pressure only | 2 inch | $250 to $450 | Set pressure, spring material |
| Combined pressure-vacuum | 1.5 to 2 inch | $320 to $600 | Two seats, additional machining |
| Combined, large or PTFE seated | 3 inch | $450 to $800 | Size, elastomer, documentation |
The size establishes the base price, while the documentation increases it more than what the buyer thinks. A valve that comes with a material certificate, elastomer declaration and set pressure test record costs 15–30% more than the same valve in a bag; this is what a pharmaceutical or dairy audit will require.
The finish is the third variable. The standard Ra 0.8 finish is the default; an Ra 0.4 finish for a pharmaceutical line requires a separate machining process and therefore has a separate price. A buyer specifying "sanitary" without a number for the finish has given the supplier the option to choose.
Manufacturers and How They Differ
Dixon Sanitary is the familiar name to most buyers for clamp fittings; Dixon Sanitary's relief valve range uses the same connection system as Dixon Sanitary's other fittings; therefore, there is a practical advantage in having one clamp standard for all of Dixon Sanitary's fittings. Alfa Laval and GEA provide pressure valves with documentation that matches the tanks and heat exchangers of their suppliers. SPX Flow sells dairy and beverage ranges under the Waukesha Cherry-Burrell brand.
There are three key distinctions. Firstly, the way you connect to your equipment, and whether you're connecting to other equipment within the same plant. Secondly, the type of documentation package you receive — In many cases, pharmaceutical suppliers differ from general suppliers in this area. Thirdly, the range of set pressures and methods for adjusting pressure. Any pressure-relief valve that requires you to return it back to the manufacturer for adjustment will have to be returned for adjustments at the manufacturer's facility.
The comparative analysis of the various types of pressure valves shows the general areas of application for spring valves, rupture discs, and pilot-operated pressure valves; this analysis precedes the selection of specific brands.

Choosing by Application
A valve with a low setpoint (spring only pressure configuration) and a larger valve (pressure-vacuum configuration) are the best options for tanks because of the various flow rates generated from steam/air leakage through the jacket and the utility connection, and control valve failures. Thus, each configuration has its own limitations with regard to maximum allowable flow rate. The combined pressure-vacuum configuration of the pressure-vacuum valve is suitable for process vessels utilized for cleaning, filling, and emptying with high POS usage rates. Pressure-vacuum valves are also the configuration suitable for other types of process vessels. A valve that only relieves pressure protects against one of the types of failure but not the other.
It is important to select a pressure valve based on its application. As shown in the table below, a dairy receiving tank requires a combination of both pressure and vacuum pressure relief valves, whereas a brewery fermenter requires only a pressure-relief valve (plus a separate vent) due to the fact that CO2 is generated during production, and there is no risk of creating a vacuum within the fermenter.
| Application | Type | Set pressure | Notes |
|---|---|---|---|
| Dairy receiving tank | Combined pressure-vacuum | 0.5 to 1.5 bar | Emptying pulls vacuum, CIP pressurises |
| Brewery fermenter | Pressure only, plus a vent | 1.5 to 2.5 bar | CO2 generation, no vacuum risk |
| Beverage mixing vessel | Combined | 1 to 2 bar | Cleaning cycle dominates |
| Pharmaceutical reactor | Pressure only, PTFE seat | Per vessel rating | Documentation and finish decide the supply |
| Pump discharge protection | Pressure only | Below pump rating | Sized on pump capacity, not line size |
| CIP supply line | Pressure only | Per line rating | Must see cleaning flow to stay clean |
When reviewing the table, it is critical to look at the vessel's operation rather than the product contained within the vessel. A tank that is filled and emptied will require the vacuum side of the pressure valve, while a tank that is only pressurised will not require a vacuum side. The size of the valve on a line containing product should be small with a low preset setting, due to the fact that thermal expansion of product will create a slow volume increase of product.
If a relief valve protects a pump instead of a vessel, the size of the relief valve is determined by the pump curve. A positive displacement pump's relief requirement is its full flow at the set pressure, which is a larger valve than the discharge line would suggest, which is why a pump protection valve is often one size above the line it sits on.
Lines requiring both non-return and relief protection cannot use just a single device; therefore, checking the difference between a check valve and a pressure relief valve is essential to ensuring you have the right device for your line. If you need relief protection but install a check valve in lieu of a relief valve, you will not provide any protection to the line.
Our Range and What It Covers
We make sanitary relief valves out of 316L with either EPDM, silicone, or PTFE seats, in pressure-only or combined pressure-vacuum configurations, ranging from 1 inch to 3 inch tri-clamp, and with set pressures ranging from 0.2 to 6 bar which are all pre-set and locked at the factory, and are additionally verified on a test bench prior to shipping. The body is machined to Ra 0.8 with a Ra 0.4 option, and the material and elastomer certificates accompany the valve and are not provided upon request.
Being a factory as opposed to a distributor is the major difference when you are placing a project order. When the specified valve configuration is received from the factory, it is completely manufactured to meet the customer's specifications and may therefore differ from any existing stock configuration. This applies to the configuration of the pressure and vacuum relief valve, which has been configured in the same manner as all other valves in the same series; the valve has been manufactured with a second seat.
As a result of this configuration process, the customer receives a factory-direct price and a complete documentation package with every order placed (which can consist of either a single replacement or a project requiring multiple valves).
FAQ
What is the three-rule requirement of pressure relief valves?
The "three rule" refers to the allowable pressure drop between the vessel (or tank) and the pressure relief valve. In order to accurately sense the correct pressure inside the vessel, the pressure drop must not exceed three percent of the set pressure; otherwise, the valve will detect the reduced pressure downstream due to the use of an incorrectly sized or too long nozzle and will incorrectly set the pressure at which the vessel is protected. The same three percent rule may apply to the discharge side of a pressure relief valve; a too high return pressure can change the set point of most conventional valves.
What is a sanitary control valve?
A sanitary control valve is any type of valve that is manufactured to a specific food hygienic standard suitable for contacting the product; the sanitary valve will typically have a body made of only 316L stainless steel, clamp or weld connections, a Ra 0.8 or better surface finish, and no dead spots, and any elastomers used will comply with FDA standards. A sanitary control valve can include any of the following: a sanitary relief valve, modulating control valve, butterfly valve, or diaphragm valve. The sanitizing function is determined by two factors: the ability to be cleaned and whether there is documentation of the valve.
What are two types of pressure relief valves?
There are two general categories of pressure relief valves: those which reclose after lifting (spring-loaded) and those which do not (rupture disc). The former group has the following categories: pressure-only; combined pressure/vacuum; pilot operated.
Where should a pressure relief valve be installed?
Pressure relief valve installations must be done vertically and located on the highest point of the pressure vessel using an appropriately sized nozzle with a short distance from the vessel; there shall not be any pipe isolation between the valve and vessel unless the valve is locked open. The discharges from these valves must be routed to a safe location using the pipe size corresponding to the valve's outlet with no restrictions (including shut-off valves).
References
- Dixon — Sanitary Pressure Relief and Vacuum Valves
- Alfa Laval — Hygienic Valves and Tank Equipment
- GEA — Sanitary Process Components and Safety Devices
- SPX Flow — Waukesha Cherry-Burrell Hygienic Valves
- 3-A Sanitary Standards — Hygienic Equipment Design Criteria
Conclusion
The specification for a sanitary relief valve includes three specific numbers and an elastomer selection which will withstand the direct effect of CIP (Cleaning In Place) chemistry. The number of the set point establishes what pressure the vessel is protected at and the flow capacity establishes a flow rate at the set point. The elastomer selection establishes whether the valve will continue to seal after 100 CIP cycles.
The installation of a valve, whether it meets all of the specifications or not, dictates how effective a valve will be. In addition to installing the valve vertically on the highest point in the tank with a short inlet, there must not be an isolating valve and the discharge must be routed away from people and allow for an unrestricted flow. If a valve is installed behind an isolating valve, then it will not provide any protection, and that is typically the first failure identified during an audit.